American Standard Heritage Bidet 5032.010 User Manual

Browse online or download User Manual for Unknown American Standard Heritage Bidet 5032.010. American Standard Heritage Bidet 5032.010 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
K1
© 2008 AS America Inc.
HERITAGE™ BIDET
VITREOUS CHINA
HERITAGE™ BIDET
5032.026 For deck-mounted tting (illustrated)
Vitreous china
Flushing rim and vertical cleansing spray
Integral overow
Concealed oor anchor bracket
Two bolt caps
Shown with 2373.401 Eneld tting with
handles (not included)
5032.010 For over-the-rim tting
Vitreous china
Punched for single hole, over-the-rim tting,
less ushing rim and spray
Integral overow
Two bolt caps
Nominal Dimensions:
654 x 359 x 362mm
(25-3/4" x 14-1/8" x 14-1/4")
Compliance Certications -
Meets or Exceeds the Following Specications:
• ASME A112.19.2M for Vitreous China Fixtures
Revised 2/08
To Be Specied:
Color: White Bone Linen
Bidet Fitting*:
Fitting Finish:
Trap:
Supplies with Stops:
* See faucet section for additional models available
222mm
(8-3/4)
76mm (3)
SUGGESTED
MINIMUM
114mm
(4-1/2)
127mm
(5)
654mm
(25-3/4)
76mm
(3)
432mm
(17)
241mm
(9-1/2)
127mm
(5)
114mm
(4-1/2)
SUPPLIES
AS REQUIRED
C/L OF DRAIN OUTLET
362mm
(14-1/4)
C/L OF 3/8 HOT & COLD INLETS
203mm
(8)
102mm
(4)
FINISHED
WALL
COUPLING
NUTS ON
FITTING
359mm
(14-1/8)
29mm (1-1/8) DIA. HOLE
FOR SPRAY
44mm (1-3/4) DIA. STD.
DRAIN OUTLET
C/L
64mm
(2-1/2)
19mm
(3/4)
C/L OF (2) 8mm (5/16) DIA. FOOT
ANCHOR HOLES ON 76mm (3") CENTERS
(3) 35mm (1-3/8) DIA.
VALVE HOLES
25mm (1) DIA. HOLE
FOR POP-UP ROD
FINISHED
FLOOR
1-1/4 O.D. TAILPIECE
241mm
(9-1/2)
REF.
*
279m
m
(11
)
HANGER
VACUUM
BREAKER
73mm
(2-7/8)
MIN.
NOTES:
*
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES ARE SUGGESTED.
P” TRAP AND FITTINGS NOT FURNISHED WITH BIDET AND MUST BE
ORDERED SEPARATELY. BIDET FITTING HAS TRANSFER VALVE
FEATURE.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BIDET AND
FITTING FOR ADDITIONAL INFORMATION.
PROVISIONS MUST BE MADE FOR THE INSTALLATION OF TRAP IN
FLOOR.
IMPORTANT: Dimensions of xtures are nominal and may vary within the
range of tolerances established by ANSI Standard A112.19.2.
These measurements are subject to change or cancellation. No responsibility
is assumed for use of superseded or voided leaet.
Page view 0
1

Summary of Contents

Page 1 - HERITAGE™ BIDET

K1© 2008 AS America Inc.HERITAGE™ BIDETVITREOUS CHINAHERITAGE™ BIDET❑ 5032.026 For deck-mounted tting (illustrated)• Vitreous china • Flushing rim a

Comments to this Manuals

No comments