American Standard Afwall Wall 1.6 GPF Flush Valve Wall-Mounted Toilets 2258 User Manual

Browse online or download User Manual for Unknown American Standard Afwall Wall 1.6 GPF Flush Valve Wall-Mounted Toilets 2258. American Standard Afwall Wall 1.6 GPF Flush Valve Wall-Mounted Toilets 2258 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SAVE FOR FUTURE USE
1
730484-100
Saniwares
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2000
!
2
Refer to instructions supplied with wall carrier for proper installation of 4-bolt support
system wall cavity requirements and rough-in information for waste outlet piping.
Closet Carrier Support
Putty Knife
Sealant
Tape Measure
Regular Screwdriver
Adjustable Wrench
Carpenters Level
Flush Valve
RECOMMENDED TOOLS AND MATERIALS
Pictures may not exactly define contour of china
Model 2254, 2256, 2257, 2258
AFWALL 1.6 GPF FLUSH VALVE
WALL-MOUNTED TOILETS
INSTALLATION INSTRUCTIONS
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this
product is installed properly, please read these instructions carefully before you begin. (Certain installations may
require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR
HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY!
NOTE:
For proper operation product requires a minimum of 30 psi working line pressure
FIXTURE MOUNTING
Fixture studs should project
1-7/8" (48mm) from face of
finished wall.
Front View
Side View
FINISHED
WALL
1-7/8"
(48mm)
(4) STUDS
Meets the American Disabilities Act Guidelines and ANSI A117.1
Requirements for the Physically Challenged
When installed,
top of seat is
17" to 19"
(432mm to 483mm)
from the finished
floor.
FINISHED WALL
470mm
(18-1/2)
C/L OF SEAT POST
HOLES 140 mm
(5-1/2) CENTER
635mm
(25)
73mm
(2-7/8)
184mm
(7-1/4)
133mm
(5-1/4)
191mm
(7-1/2)
292mm
(11-1/2)
(4) 22mm
(7/8)
HOLES
375mm
(14-3/4)
C/L OF
OUTLET
121mm
(4-3/4)
FINISHED
FLOOR
32mm
(1-1/4)
381mm
(15)
or
432mm
(17)
381mm
(15)
or
432mm
(17)
1" N.P.T. OR C.W.T. SUPPLY
AS REQUIRED TO FLUSH VALVE
330mm
(13)
19mm
(3/4)
133mm
(5-1/4)
98mm
(3-7/8)
70mm
(2-3/4)
1-1/2 SPUD
C/L
229mm
(9)
FINISHED WALL
470mm
(18-1/2)
C/L OF SEAT POST HOLES
140mm(5-1/2) CENTERS
635mm
(25)
191mm
(7-1/2)
298mm
(11-3/4)
(4) 22mm (7/8)
DIA. HOLES
375mm
(14-3/4)
C/L OF
OUTLET
FINISHED
FLOOR
32mm
(1-1/4)
330mm
(13)
(3/4)
19mm
133mm
(5-1/4)
98mm
(3-7/8)
C/L
229mm
(9)
38mm (1-1/2) DIA. HOLE IN WALL
95mm
(3-3/4)
FOR WALLS UP TO 1" IN THICKNESS FOR EACH INCH
ADDITIONAL THICKNESS OF WALL ADD 25mm (1) TO
MEASUREMENT SHOWN
89mm
(3-1/2)
1" C.W.T. OR N.P.T. SUPPLY
AS REQ'D NOT FURNISHED
121mm
(4-3/4)
VACUUM BREAKER
76mm(3) DIA. HOLE IN WALL
FOR 1-1/2 SPUD
254mm
(10)
41mm
(1-5/8)
38mm
(1-1/2)
70mm
(2-3/4)
or
184mm
(7-1/4)
133mm
(5-1/4)
or
Page view 0
1 2

Summary of Contents

Page 1 - WALL-MOUNTED TOILETS

SAVE FOR FUTURE USE1730484-100SaniwaresProduct names listed herein are trademarks of American Standard Inc.© American Standard Inc. 2000 !2Refer to in

Page 2

Place back-up nuts on both bottom bolts, andthe top left-hand bolt only.Adjust the two lower back-up nuts so that frontface of nuts is flush with fini

Comments to this Manuals