American Standard 7038.400 Troubleshooting Guide

Browse online or download Troubleshooting Guide for Sanitary ware American Standard 7038.400. American Standard 7038.400 Troubleshooting guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
3
5
4
4
Certified to comply with ANSI A112.18.1
Installation
Instructions
Bidet Faucet and Transfer Valve with
EverClean™ Finish & SpeedConnect™ Drain
Congratulations on purchasing your American Standard
faucet with EverClean finish and Speed Connect drain, two
features found only on American Standard faucets.
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Turn off hot and cold water
supplies before beginning.
CAUTION
1
BIDET FAUCET INSTALLATION
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
COLD
HOT
BIDET
LEDGE
10
3a
3
8
9
1
5
2
6
Roughing-in
Dimensions
SPRAY INSTALLATION
2
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
PUTTY
6
2
7
8
1
9
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread DECK ADAPTER (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
Place RUBBER RING (10) into DECK ADAPTER (4).
MOUNTING
SURFACE
4
10
2
1
3, 3a
5/16''
MIN.
Fig. A.
11
Adjustable Wrench
Screwdriver
Channel Locks
Required tools
Tubing Cutter
Phillips Screwdriver
Plumbers' Putty or
Caulking
7
1
SpeedConnect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
BIDET OUTLINE
IS SYMBOLIC
FINISHED
FLOOR
FINISHED
WALL
1-1/4 O.D. TAILPIECE
DOUCHE
SPRAY
2-1/8
DIA.
ADJ. 1-1/4
TO 2-1/4
3-7/8
5-1/2
1-3/8
DIA.
7/8 DIA.
1-1/4
MAX.
1-3/16
DIA.
2-1/4
DIA.
(C)
(H)
4-1/4
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
8 TO 12
EverClean Finish
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
TROPIC
M968893
7038.400
4
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Instructions

3544Certified to comply with ANSI A112.18.1InstallationInstructionsBidet Faucet and Transfer Valve withEverClean™ Finish & SpeedConnect™ Drain Con

Page 2

CHECK DRAIN CONNECTIONS1213TEST INSTALLED FITTINGWith HANDLES (1) in OFF position, turn on WATERSUPPLIES (2) and check all connections for leaks.Opera

Page 3

Speed Connect™ DrainTroubleshooting GuideDisconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.Look at th

Page 4 - OUTLINE OF BIDET

6STOPPER INSTALLATION PROCEDURELocked Mode: Look at the Plastic Loop at the bottom of the Stopper and noticethat the Loop is on one side of the Stoppe

Page 5 - SpeedConnect™ Drain

M968893POP-UP DRAINTighten TAILPIECE (4) on DRAIN BODY beforeinstalling DRAIN BODY. Fig. B.3542TIGHTEN LOCKNUT1REMOVE FLANGEThread FLANGE (1) counter-

Page 6

Connect HOT water supply to inlet of left SHANK and COLDwater supply to right SHANK using sealant, appropriateconnectors, and COUPLING NUTS.Connect 1-

Page 7

CHECK DRAIN CONNECTIONS1213TEST INSTALLED FITTINGWith HANDLES (1) in OFF position, turn on WATERSUPPLIES (2) and check all connections for leaks.Opera

Page 8

M968893SpeedConnect™ DrainTroubleshooting GuideDisconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.Look

Page 9

M9688936STOPPER INSTALLATION PROCEDURELocked Mode: Look at the Plastic Loop at the bottom of the Stopper and noticethat the Loop is on one side of the

Page 10 - M968894 Rev. 1.1

3544Certified to comply with ANSI A112.18.1InstallationInstructionsBidet Faucet and Vacuum Breaker withSpeed Connect™ Drain Turn off hot and cold water

Page 11 - Speed Connect™ Drain

POP-UP DRAINTighten TAILPIECE (4) on DRAIN BODY beforeinstalling DRAIN BODY. Fig. B.3542TIGHTEN LOCKNUT1REMOVE FLANGEThread FLANGE (1) counter-clockwi

Page 12 - M 9 6 8 8 9 4 Rev. 1.1

Connect HOT water supply to inlet of left SHANK and COLDwater supply to right SHANK using sealant, appropriateconnectors, and COUPLING NUTS.Connect 1-

Comments to this Manuals

No comments