American Standard 2711 User Manual

Browse online or download User Manual for Sanitary ware American Standard 2711. E085 - Atos

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Valve configuration, see section :
61 = single solenoid, center plus external position, spring centered
63 = single solenoid, 2 external positions, spring offset
67 = single solenoid, center plus external position, spring offset
70 = double solenoid, 2 external positions, without springs
71 = double solenoid, 3 positions, spring centered
75 = double solenoid, 2 external positions, with detent
Other configurations are available on request
Solenoid pilot valve:
I = DHI for AC and DC supply with
CURUS
certified solenoids
E =
DHE for AC and DC supply, high performances
with
CURUS
certified solenoids
www.atos.com
Solenoid directional valves type DPHI and DPHE
two stage, ISO 4401 size 10, 16, 25 and 32
Table E085-6/E
Spool type, two stage directional valves
with solenoids certified according to North
American standard cURus, available in two
different executions:
DPHI for AC and DC supply, solenoid
pilot type DHI, see tech. table E010
• DPHE high performances, for AC and DC
supply, solenoid pilot type DHE see
tech. table E015
Single and double solenoids versions are
available in two or three position configura-
tions and with a wide range of interchan-
geable spools , see section
.
Standard coils protection IP65 and they are
easily replaceable without tools.
The valve body is made by shell-moulding
casting with wide internal passages.
The valves can be supplied with optional
devices, see section
for available
options.
Surface mounting: ISO 4401, size 10, 16,
25 and 32
Max flow up to 160, 300, 700, 1000 l/min.
Pressure up to 350 bar
E085
1 MODEL CODE
DPH
Two stage directional control valve
271 24DC1 /*
Series
number
I
-
Spool type, see section
Options, see section
/A X **
DPHE-471*/H
Valve size:
1 = 10 2 = 16 4 = 25 6 = 32
Voltage code, see section
X = without connector
See section
for available connectors, to be ordered separately
00 = solenoid valve without coils (for DPHI)
00-AC = AC solenoid valve without coils (for DPHE)
00-DC = DC solenoid valve without coils (for DPHE)
NOTES (see also section 4,2 for special shaped spools):
- For DP*-1 are available only spools: 0, 0/2, 1, 1/2, 3, 4, 5, 58, 6, 7
- For DP*-6 are available only spools: 0, 1, 1/2, 2, 3, 4, 5, 58, 6, 7, 8, 19, 91
12
12
12
102
10
12
02
10
71
63
61
75
67/A
63/A
61/A
67
2
CONFIGURATIONS and SPOOLS (representation according to ISO 1219-1, for functional scheme, see section )
0
8
49
1
90
16
2
09
17
3
91
58
4
19
5
93
6
39
7
94
0/2
1/2
2/2
0102
0102
0102
0102
0102
70
Configurations Spools Configurations Spools
Seals material:
omit for NBR (mineral oil
& water glycol)
PE = FPM
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1

Valve configuration, see section :61 = single solenoid, center plus external position, spring centered63 = single solenoid, 2 external positions, spr

Page 2 - Code of spare coil

1024 NOTES4.1 Options/A = Solenoid mounted at side of port A of main body (only for single solenoid valves). In standard version, solenoid is mounted

Page 3

Valve pressure drop Δp [bar]Flow [l/min]DPH*-16FLOW VERSUS PRESSURE DIAGRAMS Based on mineral oil ISO VG 46 at 50°CABCDEFSpool typeFlow directionSp

Page 4 -  Spring

8SWITCHING TIMES (average values in m sec)Notes:1) For configuration 70 and 75, times of switching ON and switching OFF are the same: this value is eq

Page 5

10 PLUGS LOCATION FOR PILOT/DRAIN CHANNELSDepending on the position of internal plugs, different pilot/drain configurations can be obtained as shown b

Page 6

ISO 4401: 2005Mounting surface: 4401-05-05-0-05DPHI-2*Fastening bolts:4 socket head screws M6x40 class 12.9Tightening torque = 15 NmDiameter of ports

Page 7

12 DIMENSIONS FOR DPH*-4 [mm]DPHI-4*/HDPHI-3*/H9DPHI-4*E085Overall dimensions refer to valves with connectors type 666DPHE-4*maxDPHI-4*Stroke adjustme

Page 8

The subplates are supplied with fastening bolts. For further details see table K28013 DIMENSIONS FOR DPH*-6 [mm]Overall dimensions refer to valves wit

Comments to this Manuals