American Standard 2275.509.002 Installation Guide

Browse online or download Installation Guide for Sanitary ware American Standard 2275.509.002. American Standard 2275.509.002 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
COLONY SOFT
2275.409
2275.509
Insert FAUCET (1) and CABLE CONNECTOR (2) through center hole
of mounting surface. Fig. A.
From under side of mounting surface thread the two MOUNTING
NUTS (3) onto FAUCET SHANKS (4). Fig. B.
Center FAUCET (1) and hand tighten MOUNTING NUTS (3) to
secure FAUCET (1).
1
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet
with Speed Connect™ Drain
INSTALL FAUCET
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
Tubing Cutter
Congratulations on purchasing your American Standard faucet
with the Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with
the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these
instructions carefully before you begin.
Fig. A.
Fig. B.
1
M968876 Rev. 1.2
Plumbers' Putty or Caulking
(HAND TIGHTEN)
3
1
2
4
3
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Apply a bead of putty along the edge of the underside of the FAUCET (1).
PUTTY
C
H
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Instructions

COLONY SOFT2275.4092275.509Insert FAUCET (1) and CABLE CONNECTOR (2) through center holeof mounting surface. Fig. A.From under side of mounting surfac

Page 2 - Fig. A. Fig. B

M968876 Rev. 1.2 Thread FLANGE (1) counter-clockwise and removeFLANGE (1) and FOAM GASKET (2) from drainbody. Fig. A.Thread LOCKNUT (3) clock-wise

Page 3 - “p” trap

Operate LIFT KNOB (1) to verify that STOPPER (2) opens andcloses.Note: If STOPPER (2) does not open and close properly thenrefer to the “troubleshooti

Page 4 - “P” TRAP

124CARE INSTRUCTIONS:DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.DO NOT: DO NOT CLEAN THE PRODUCT WITH

Page 5 - Speed Connect™ Drain

Speed Connect™ DrainTroubleshooting GuideDisconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.Look at th

Page 6 - M968876 Rev. 1.2

STOPPER INSTALLATION PROCEDURELocked Mode: Look at the Plastic Loop at the bottom of the Stopper and noticethat the Loop is on one side of the Stopper

Comments to this Manuals

No comments