12-1263-02 7
AUD2 Product Specifications 1
MODEL
RATINGS
2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
AFUE (ICS)
Temp. Rise (Min.-Max.) °F.
BLOWER DRIVE
Dia.-Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts/Ph/Hz
COMBUSTION FAN — TYPE
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
FL Amps
FILTER — Furnished?
Type Recommended
Filter (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
DIRECT IGNITION DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V/Ph/Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
General
Data
AUD2B080A9482A
52000
41600
80000
63000
80.0
30 - 60
DIRECT
10 x 8
1
4
SEE FAN PERF. TABLE
1/3
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
1.0
YES
HIGH VELOCITY
1 - 17 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 45
4 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
4
115/1/60
8.9
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
142/132
AUD2D100A9362A
65000
52000
100000
79000
80.6
40 - 70
DIRECT
10 x 7
1
4
SEE FAN PERF. TABLE
1/3
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
0.93
YES
HIGH VELOCITY
1 - 17 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
5
115/1/60
8.4
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
151/141
AUD2C100A9482A
65000
52000
100000
79000
81.0
35 - 65
DIRECT
10 x 8
1
4
SEE FAN PERF. TABLE
1/2
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
0.93
YES
HIGH VELOCITY
1 - 20 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
5
115/1/60
11.0
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
162/151
AUD2C100A9602A
65000
52000
100000
80000
80.0
30 - 60
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
0.93
YES
HIGH VELOCITY
1 - 20 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITOR
IN-SHOT
5
115/1/60
12.8
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
162/151
1
Central Furnace heating designs are certified by AGA and ETL.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian