INSTALLATION INSTRUCTIONS
752869-100 Rev. D
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
VIRTUOSO ELITE™
WHIRLPOOL
7236E SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
GENERAL SPECIFICATIONS FOR 7236E WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP
72 x 36 x 21-1/4 In. (1829 x 914 x 540mm)
101 Lbs. (45 Kg.)
751 Lbs. (338 Kg.)
78 Gal. (296 L)
69 Gal. (262 L)
46 x 18 In. (1168 x 457mm)
66 x 30-1/2 In. (1676 x 775mm)
15-3/4 In.(400mm)
42 Lbs./Sq.Ft. (204 Kgs./Sq.m)
25.6
49.4
2.1 HP,14.4 AMPS,120V.
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
• Flex-Jet Soft Jet Kit*
• 6 Foot Apron*
• E-Z-Install Heater*
• Tile Bead Kit*
List of Required Components (not included):
• Drain* • Bath Filler*
* see your Home Depot Retailer
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp GFI
Outlet
• Cement, Plaster,
Grout
1829mm
(72)
914mm
(36)
914mm
(36)
279mm
(11)
102mm
(4)
470mm
(18-1/2)
19mm
(3/4)
TYP.
178mm X 356mm
(7 x 14) CUTOUT
OUTLINE OF CUTOUT
1791mm X 876mm
(70-1/2 X 34-1/2)
PUMP
ON/ OFF
SWITCH
C/L OF
DRAIN
51mm
(2)
489mm
(19-1/4)
ROUGH FLOOR
1-1/2 O.D.
TAILPIECE
76mm
(3)
PROVIDE ACCESS
TO PUMP FOR SERVICE
ON ALL INSTALLATIONS
540mm
21-1/4
C/L OF
OVERFLOW
IN-LINE HEATER
REMOVABLE BLANK
1-1/2 N.P.T. THREAD
INTEGRAL
FEET
LEVELING
STRINGER
NOT FOR
SUPPORT
44mm
(1-3/4)
89mm
(3-1/2)
RECOMMENDED
FITTING LOCATION
64 X 279mm (2-1/2 X 11)
Page view 0
1 2 3 4

Summary of Contents

Page 1 - 7236E SERIES

INSTALLATION INSTRUCTIONS752869-100 Rev. D© American Standard Inc. 2003All product names listed herein are trademarksof American Standard Inc. unless

Page 2 - TYPICAL RECESS INSTALLATION

TYPICAL PIER TYPE INSTALLATIONAS DESIRED34-1/2(876 mm)CUTOUTAS DESIRED70-1/2(1791 mm)CUTOUT19-1/4(489mm)ACCESS PANEL24 (610 mm)12(305 mm)MOUNT

Page 3 - ELECTRICAL DIAGRAM

ELECTRICAL DIAGRAMREAD AND FOLLOW ALL INSTRUCTIONSBLACKWHITE120 VACGND.20 AMP GFCIOUTLETWHIRLPOOL MOUNTEDAIR SWITCH ORWALL TIMER ELECTRICAL INSTALLATI

Page 4 - SPIC AND SPAN

WIRE SELECTION GUIDE752869-100 Rev. DDRAIN CONNECTION AND SYSTEM TESTUsing recommended drain opening, connect whirlpool drain to waste line. Tighten